High Performance NFPA1971 Structural Firefighter Suit

FOB Reference Price:Get Latest Price
US $220-299 / Sets | 50 Set/Sets (Min. Order)
Report Suspicious Activity
Overview
Quick Details
Place of Origin:
Guangdong, China (Mainland)
Brand Name:
U.protec
Model Number:
UXF-011
Material:
Nomex Advance
Standards:
EN469
Color:
navy blue, light yellow, orange, lime green
Size:
XS-XXXXL
Supply type:
OEM service
Style:
firefighter suit
Color fastness:
4-5 grade
Features:
FR, anti-static, waterproof and heat insulation
Brand:
U.protec
Structure:
standard four layers
Supply Ability
Supply Ability:
50000 Set/Sets per Month
Packaging & Delivery
Packaging Details
1pc/polybag,10pcs/carton,carton size 58X40X80cm,cross weight:25kgs more or less
Port
Shenzhen
Lead Time :
30-40 working days

 

Product Description

 

ITEMUL Certified firefighting suits
Model#UXF-X08-018
MaterialNomex ripstop , 7 oz/yd² Outshell, Stedair 3000 moisture barrier, 100% Kevlar thermal barrier and Nomex blended linner
SizeXS to 4XL
ColorNavy blue ,orange,Khaki color
DescriptionGreater Flexibility for More Comfort
Flame-resistant, waterproof, PTFE moisture and comfortable linner Curved shape design at elbow and knee to move convenient. Arm hole design to provide extra length of sleeves and make human body move without restriction.
Details•Front closed by heavy duty FR zipper and FR Velcro.
•Two big patch pocket , one radio pocket on left chest ,closed by Velcro.
•FR yellow silver yellow reflective tape in 3” width 3M 9587
•High collar fully lined with throat closure tab
•FR drainage mesh into waist hem and bottom pocket
•100% Kevlar Knitted cuffs with thumb hole
•Elasticated braces with quick release buckles
•Kevlar DRD system
•Reinforced at knee by leather .
StandardUL certified by standard NFPA1971 2013
MOQ50pcs
Sample Time7-10 working days
Sample Chargerefundable after placing order
Lead Time45days
Packing10pcs/ctn, Ctn size: 58*40*80cm, G.W.: 30kgs/N.W.: 28kgs
Payment TermsT/T, 30%deposit, 70% against with B/L copy

 

 

Images of Product

 

 

 

 

 

 

 

 

Detailed Images

 

 

 

 

About U.Protec

 

 

 

Certifications

 

 

Our Exhibitions

 

                                                                            Beijing Exhibition

                                                                      Guangzhou Exhibition

                                                                    Shanghai Exhibition

                                                                  German A+A Exhibition

                                                                      America Exhibition

                                                                      Brazil Exhibition

 

 

Our Services

 

 Service we supply                                                                                                                             

1) The new design and new materials are provided as your requirements;
2) We are pleased to be given a test order;
3) The OEM services are available;
4) One-stop service: Satisfy what you want;

 

 If you have design want to make, we can do as follows:           Web:www.uprotec.com/web                  

1) You send us your design (samples or pictures or some ideas), so that we could know what you want exactly;
2) We make the samples for you then send you the pictures and samples by express;
3) As soon as you receive the samples and approve to us (if any changes we will follow them), then you can place the order to us;

 

 

Care & Maintenance

PROPER WEARING

    FR clothing can only provide protection if the wearer follows garment manufacturers' recommendations for proper use:

    *Wear garments properly – collars closed, sleeves and cuffs down and secured, shirt tails tucked, closures secured, and other manufacturer recommendations.

    *Wear looser-fitting garments that provide adequate mobility.

    *Do not wear non-FR clothing over FR garments. The outermost layer must be FR

    *Wear only FR or non-melting undergarments (e.g. cotton, silk, wool.)

    *Wash garments thoroughly after each wearing to remove contaminants.

    *Do not put on or take off the garment in proximity of flammable gasses, vapors, dusts or in other potentially explosive environments.

    *In potentially explosive atmospheres, proper grounding procedures must be used.

    *Wear garments with the appropriate arc rating as dictated by an electric arc hazard analysis. Consult employer if unsure.

 

CARE TIPS:

    Most flame-resistant garments can be handled safely using common laundering and care procedures. However, a few precautions must be followed to ensure your FR garments maintain their maximum effectiveness. Remember: FR clothing is safety equipment that just might save your life. It is imperative to make sure your FR garments are properly cleaned and maintained.

    Carefully follow the manufacturer's care label when laundering FR garments. Many FR fabrics require mild wash and dry conditions to maximize the life of the garment.

    *Wash new flame-resistant garments prior to wearing.

    *Wash flame-resistant garments separately from standard clothing.

    *Do not use chlorine bleach.

    *Make sure FR garments are clean and in proper repair before each wearing.

    *Remove oils and flammable contaminants from FR garments. Flammable contaminants can be a fuel source that adds to burn injury.

    *Repair garments using "like materials." Use FR fabric, thread and components. Return garments to the manufacturer for repair, or use an authorized FR repair facility.